Q&A


tom tom
How do I calculate pond evaporation rates? View All


16 years ago - 5 months left to answer. - 1 response - Report Abuse
Respond to question
    0      [lnkReport]        0       0       
Share |
  Responses


Jason
There are a few factors when calculating the water evaporation rates from ponds or lakes, among the more important ones are wind velocity. I recommend you study the ASHRAE model: W = [A + (B)(V)](Pw - Pa)/Hv where: W = water evaporation rate, (lb/hr) per sq.ft. of pond surface area A = a constant = 95 B = a constant = 37.4 V = air velocity over the pond surface, miles/hr Pw = vapor pressure of water at the pond water temperature, inches of Hg Pa = vapor pressure of water at the air dewpoint temperature, inches of Hg Hv = heat of vaporization of water at the pond water temperature, Btu/lb A good set of Steam Tables will provide you with the latent heat of vaporization and the vapor pressure of water at the temperatures involved. The vapor pressures may be provided in units other than inches of Hg, and you will need to make the conversion.

**There was a study by the Department of Energy that concluded ASHRAE equation was more accurate if A was taken as 68 (instead of 95) a


16 years ago

Source:


  0     0         

ENGINEERING.com does not provide engineering advice. The Ask@ service is a forum for members to exchange ideas relating to the world of engineering. We caution users not to accept any responses that they receive without further validation, and not to rely on any engineering advice that they may get from other members of the Ask@ forum. ENGINEERING.com specifically disclaims any obligation to validate or verify any information posted within the Ask@ service. ENGINEERING.com encourages users to seek the services of a professional engineer for any engineering advice they may require.