Thermocouple Requirement for PWHT

Thermocouple Requirement for PWHT

For PWHT of pipe, what is the minimum requirement of Thermocouple with respect to diameter and according to which clause of the relevant Code/Standard.
If one element is used to carry out PWHT of 4-6 scattered weld joints of small bore then only one thermocouple is sufficient OR not to represent all joints.

Most components shall have 3 separate locations for thermocouple placement. 1) centerline of weld, 2) edges of soak band (SB) and 3) edges of heated band (HB). For NPS 8 and less it usually is 1 TC at 12:00 for weld centerline, monitoring at 6:00 at both edges for the SB, and monitoring at 12:00 for both edges of the HB. Based on the thickness,diameter and space between the scattered joints, PWHT temperature and material,One TC would not be a proper representation of all weld joints. The owner should have a Operating Procedure to address PWHT requirements.