Register     Login    My Engineering
Ask@  
Ask@ENGINEERING.com
All Categories
Unanswered Questions
Fun & Puzzles
General Engineering
Mechanical/Automotive
Civil/Structural
Chemical/Material
Electrical/Electronics
Industrial
Computer Engineering
View All Categories
Full Leaderboard
rahul gopinath
Level: 3
1128
Jake Banman
Level: 2
882
engr
Level: 2
752
View Full Leaderboard

Ask@ENGINEERING.com
Ask@ENGINEERING.comAll CategoriesFull LeaderboardEmail a QuestionGetting Started
Ask@ENGINEERING.com is a great place to get an answer to your practical engineering question or to share a fun puzzle. To ask or answer a question, you must login to your ENGINEERING.com account. If you are not a member, please register now. Find out more information on how to get started now.      
 
Ask@ENGINEERING.com
*Please put your question
in the subject line
Ask a Question

Bruce B
Some concrete elevator core door openings have lintel steel, some have just the default wall steel View All
In the past three years as a heavy commercial concrete foreman I have seen several designs for concrete stairwell and elevator shaft door openings. Some have no added lintel steel at all, just the default wall steel, such as #5s 12"o/c each way double mat for a 12" wall; others have very elaborate lintel steel which resembles a grade beam; others have a special lintel cage with stirrups, but I have seen cases where the stirrups were spaced further apart than the default wall steel, with smaller horizontal bars than the default. In one particular case the "lintel" steel seemed inferior to the default wall steel. In all cases, the header only needed to support standard metal decking; no extreme circumstances. It makes me wonder why there is such a disparity of ideas for similar applications. I have also seen this with foundation walls, with some walls carrying heavy stonework for several stories receiving very minimal vertical rebar support, #5s @ 4 feet on center. Why such a mix?

2 months ago - 10 months left to answer. - 1 response - Report Abuse
Respond to question
    0      [lnkReport]        0       0       
  Responses


JakeBanman
Alot of that lies with the structural engineer. Each one has their own way of deeming something as safe. It also may be that the lintel steel has been produced for lighter grade work. As far as the rebar support, #5s @ 4 feet on center, it does not take much rebar to make concrete twice as durable as it was on its own without the rebar.

If the lintel steel has indeed been made for lighter duty, it will require greater reinforcement, hence the cage with stirrups.

The decision also comes down to cost, what is he cheapest, most effective way to make it stand up?? Rebar is cheap and it greatly increases the strength of the concrete. But the main reason there is such a mix lies with the Structural Engineer; their choice is partly directed by the structure around it, the extent of the modifications to be done, and how it will affect the structural integrity.

Hope that helps.


2 months ago

Source:


  0     0         

ENGINEERING.com does not provide engineering advice. The Ask@ service is a forum for members to exchange ideas relating to the world of engineering. We caution users not to accept any responses that they receive without further validation, and not to rely on any engineering advice that they may get from other members of the Ask@ forum. ENGINEERING.com specifically disclaims any obligation to validate or verify any information posted within the Ask@ service. ENGINEERING.com encourages users to seek the services of a professional engineer for any engineering advice they may require.